{"product_id":"rki-instruments-81-sdm3r302-sdm-3r-calibration-station","title":"RKI Instruments 81-SDM3R302 SDM-3R calibration station","description":"\u003ch4 style=\"margin-bottom: 0in; line-height: normal; mso-layout-grid-align: none; text-autospace: none;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 20.0pt; font-family: 'Arial Black',sans-serif; mso-bidi-font-family: MyriadPro-Regular; mso-font-kerning: 0pt;\"\u003eRKI Instruments 81-SDM3R302 \u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-bidi-font-family: MyriadPro-Regular; mso-font-kerning: 0pt;\"\u003e$2,287.97 Free Shipping to any point in the 48 continental United States.\u003cspan style=\"mso-spacerun: yes;\"\u003e  \u003c\/span\u003eNo State or Local Sales Tax Anywhere!\u003c\/span\u003eSDM-3R calibration station \u003c\/span\u003e\u003c\/h4\u003e\n\u003cp style=\"margin-bottom: 0in; line-height: normal; mso-layout-grid-align: none; text-autospace: none;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-bidi-font-family: MyriadPro-Regular; mso-font-kerning: 0pt;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0in; line-height: normal; mso-layout-grid-align: none; text-autospace: none;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-bidi-font-family: MyriadPro-Regular; mso-font-kerning: 0pt;\"\u003eDocking Station with 3 cylinder inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0in; line-height: normal; mso-layout-grid-align: none; text-autospace: none;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-bidi-font-family: MyriadPro-Regular; mso-font-kerning: 0pt;\"\u003eWith 3 solenoids, demand flow regulator, AC adapter, flash drive, USB cable, and tubing\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0in; line-height: normal; mso-layout-grid-align: none; text-autospace: none;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-bidi-font-family: MyriadPro-Regular; mso-font-kerning: 0pt;\"\u003eWith 3 solenoids, demand flow regulator, AC adapter, flash drive, USB cable, and tubing\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eStand Alone Use (no PC required)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eCompatible with both GX-3R and GX-3R Pro\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eAutomatically charge, bump test, and\/or calibrate\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eAuto on\/off of gas detector\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e3 separate gas inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; color: black; mso-themecolor: text1;\" data-darkreader-inline-color=\"\"\u003eIncluded in the package are essential components such as a solenoid, demand flow regulator, 58AL cylinder with H2S\/CO\/CH4\/O2, cylinder holder, AC adapter, flash drive, USB cable, and tubing. Designed for stand-alone use without a PC, this system is compatible with both the GX-3R and GX-3R Pro models, allowing for automatic charging, bump testing, and calibration with convenient auto on\/off functionality for the gas detector and support for three separate gas inputs. Additionally, multiple modules—up to ten—can share one set of calibration equipment, while bump test, calibration, and alarm check records can be saved to a USB flash drive, computer, or network. The included PC software enables users to view and archive bump test, calibration records, and event data for efficient record-keeping and management.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eMultiple modules (10 max) can use one set of\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ecalibration equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eSave Bump Test, Calibration, and Alarm Check\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003erecords to USB flash drive, computer, or network\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eIncludes PC software for viewing\/archiving bump\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003etest, calibration records, and event data\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ePC-Controlled Use\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eMultiple modules connected to a PC (10 max)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eAutomatic calibration\/bump test option\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eConfigure GX-3R (Pro) parameters\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eArchive Bump Test, Calibration, and Alarm Check\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eArchive data to network location\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eSoftware controlled data retrieval\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eWindows 7, 8, and 10 compatible\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eStand Alone Use\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eThe SDM-3R is a versatile maintenance tool that automates the service of a GX-3R (Pro) portable gas monitor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eThis docking station can be used as a stand alone device for charging, calibration and bump testing, with all\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003erecords stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ePC-Controlled Use\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eAutomate how you manage and service GX-3R (Pro) instruments by connecting the SDM-3R to a computer with\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ea USB cable. With the SDM Docking Station controller software, you can simultaneously calibrate, bump test,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ealarm check, archive data, or charge up to ten instruments. You can also download the datalogging history from\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eeach instrument into one easy to manage location. SDM-3R stations can be manifolded together to reduce the\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003enumber of demand flow regulators gas cylinders required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eInput Power AC Adapter with 100 - 240 VAC, 47-63 Hz,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e0.4A input and 5.99 VDC, 2A output provided as\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003estandard.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eEnvironmental Conditions For Indoor Use Only\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e0° C to 40° C, below 95% Relative Humidity,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eNon-Condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eApplicable Instruments GX-3R and GX-3R Pro\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eMaximum Number of\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eRecords Saved\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eStand Alone: 200 calibrations, or 214 bump test, or\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e469 alarm check records\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003ePC program Controlled: Unlimited records\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e5 Ports 3 Calibration gas, 1 fresh air and 1 exhaust\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eStandard Accessories • AC Adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eUSB Flash Drive\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eInlet Air Filter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003e10 Foot Long Exhaust Tube\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eOne 3 Foot Long Tube for GAS Fitting\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eUSB Cable, Type A to Type B\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\" class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Arial Black',sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'; mso-font-kerning: 0pt; mso-ligatures: none;\"\u003eWarranty 1 year\u003c\/span\u003e\u003c\/p\u003e","brand":"Shepard Safety","offers":[{"title":"Default Title","offer_id":53863903887663,"sku":"81-SDM3R302","price":2287.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0689\/3132\/2159\/files\/81-SDM3R103_228fc586-6b99-4be3-becd-4f8c8d5959d2.png?v=1770384099","url":"https:\/\/shepardsafetyproducts.com\/products\/rki-instruments-81-sdm3r302-sdm-3r-calibration-station","provider":"Shepard Safety Products","version":"1.0","type":"link"}